Autodesk Inventor View 2019 Install and Uninstall (PowerShell)

This article will serve as an informative guide and give you a clear understanding of how to perform silent or interactive installs and uninstalls of Autodesk Inventor View 2019 using the Powershell App Deployment Toolkit. The PowerShell App Deployment Toolkit can be used to replace your WiseScript, VBScript and Batch wrapper scripts with one versatile, re-usable and extensible tool. This tool is an absolute must for Microsoft Endpoint Manager Configuration Manager (MEMCM) / (SCCM) Administrators or anyone who is responsible for packaging and deploying software.

How to Install Autodesk Inventor View 2019 Using the PowerShell App Deployment Toolkit

  1. Download the Powershell App Deployment Toolkit 3.8.4:
  2. Download the zip file to a folder created at (C:\Downloads)
  3. Open Windows PowerShell by Right-Clicking on Windows PowerShell and selecting Run as Administrator
  4. Enter the following command to remove the Zone.Identifier:
    • Unblock-File -Path C:\Downloads\PSAppDeployToolkit_v3.8.4.zip
  5. Enter the following command to extract the contents of the zip file:
    • Expand-Archive -Path C:\Downloads\PSAppDeployToolkit_v3.8.4.zip -DestinationPath C:\Downloads\PADT
  6. Enter the following commands to copy the AppDeployToolkit, Files, and SupportFiles folders to “C:\Downloads\InventorView2019”:
    • Copy-Item -Path "C:\Downloads\PADT\Toolkit\AppDeployToolkit" -Destination "C:\Downloads\InventorView2019\AppDeployToolkit" -Recurse
    • Copy-Item -Path "C:\Downloads\PADT\Toolkit\Files" -Destination "C:\Downloads\InventorView2019\Files"
    • Copy-Item -Path "C:\Downloads\PADT\Toolkit\SupportFiles" -Destination "C:\Downloads\InventorView2019\SupportFiles"

You should now see the AppDeploymentToolkit folder with files & the empty Files & SupportFiles folders at “C:\Downloads\InventorView2019”

Next we’ll want to download the EXE installer for Autodesk Inventor View 2019 & the Visual C++ Redistributable prerequisites.

  • Navigate to:
  • Download the Inventor_View_2019_English_Win_64bit_DLM.sfx.exe to a folder created at (C:\Downloads)
  • Open an Elevated Command Prompt by Right-Clicking on Command Prompt and select Run as Administrator
  • Navigate to the C:\Downloads folder
  • Enter the following command to Extract the contents of the EXE:
    • Inventor_View_2019_English_Win_64bit_DLM.sfx.exe -suppresslaunch -d "C:\Downloads"
  • Copy the contents of the extracted folder to “C:\Downloads\InventorView2019\Files\”
    • You should now see a similar structure inside the Files directory
      • 3rd Party
      • CER
      • en-us
      • EULA
      • NLSDL
      • Setup
      • SetupRes
      • x64
      • x86
      • autorun.inf
      • dlm.ini
      • Setup.exe
      • setup.ini
  • Navigate to: https://aka.ms/vs/16/release/vc_redist.x86.exe
  • Download & Copy the VC_redist.x86.exe to “C:\Downloads\InventorView2019\SupportFiles\”
  • Navigate to: https://aka.ms/vs/16/release/vc_redist.x64.exe
  • Download & Copy the VC_redist.x64.exe to “C:\Downloads\InventorView2019\SupportFiles\”
  • Copy the PowerShell script below to “C:\Downloads\InventorView2019” & name it Deploy-InventorView2019.ps1
<#
.SYNOPSIS
	This script performs the installation or uninstallation of Autodesk Inventor View 2019.
	# LICENSE #
	PowerShell App Deployment Toolkit - Provides a set of functions to perform common application deployment tasks on Windows.
	Copyright (C) 2017 - Sean Lillis, Dan Cunningham, Muhammad Mashwani, Aman Motazedian.
	This program is free software: you can redistribute it and/or modify it under the terms of the GNU Lesser General Public License as published by the Free Software Foundation, either version 3 of the License, or any later version. This program is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for more details.
	You should have received a copy of the GNU Lesser General Public License along with this program. If not, see <http://www.gnu.org/licenses/>.
.DESCRIPTION
	The script is provided as a template to perform an install or uninstall of an application(s).
	The script either performs an "Install" deployment type or an "Uninstall" deployment type.
	The install deployment type is broken down into 3 main sections/phases: Pre-Install, Install, and Post-Install.
	The script dot-sources the AppDeployToolkitMain.ps1 script which contains the logic and functions required to install or uninstall an application.
.PARAMETER DeploymentType
	The type of deployment to perform. Default is: Install.
.PARAMETER DeployMode
	Specifies whether the installation should be run in Interactive, Silent, or NonInteractive mode. Default is: Interactive. Options: Interactive = Shows dialogs, Silent = No dialogs, NonInteractive = Very silent, i.e. no blocking apps. NonInteractive mode is automatically set if it is detected that the process is not user interactive.
.PARAMETER AllowRebootPassThru
	Allows the 3010 return code (requires restart) to be passed back to the parent process (e.g. SCCM) if detected from an installation. If 3010 is passed back to SCCM, a reboot prompt will be triggered.
.PARAMETER TerminalServerMode
	Changes to "user install mode" and back to "user execute mode" for installing/uninstalling applications for Remote Destkop Session Hosts/Citrix servers.
.PARAMETER DisableLogging
	Disables logging to file for the script. Default is: $false.
.EXAMPLE
    PowerShell.exe .\Deploy-InventorView2019.ps1 -DeploymentType "Install" -DeployMode "NonInteractive"
.EXAMPLE
    PowerShell.exe .\Deploy-InventorView2019.ps1 -DeploymentType "Install" -DeployMode "Silent"
.EXAMPLE
    PowerShell.exe .\Deploy-InventorView2019.ps1 -DeploymentType "Install" -DeployMode "Interactive"
.EXAMPLE
    PowerShell.exe .\Deploy-InventorView2019.ps1 -DeploymentType "Uninstall" -DeployMode "NonInteractive"
.EXAMPLE
    PowerShell.exe .\Deploy-InventorView2019.ps1 -DeploymentType "Uninstall" -DeployMode "Silent"
.EXAMPLE
    PowerShell.exe .\Deploy-InventorView2019.ps1 -DeploymentType "Uninstall" -DeployMode "Interactive"
.NOTES
	Toolkit Exit Code Ranges:
	60000 - 68999: Reserved for built-in exit codes in Deploy-Application.ps1, Deploy-Application.exe, and AppDeployToolkitMain.ps1
	69000 - 69999: Recommended for user customized exit codes in Deploy-Application.ps1
	70000 - 79999: Recommended for user customized exit codes in AppDeployToolkitExtensions.ps1
.LINK
	http://psappdeploytoolkit.com
#>
[CmdletBinding()]
Param (
	[Parameter(Mandatory=$false)]
	[ValidateSet('Install','Uninstall','Repair')]
	[string]$DeploymentType = 'Install',
	[Parameter(Mandatory=$false)]
	[ValidateSet('Interactive','Silent','NonInteractive')]
	[string]$DeployMode = 'Interactive',
	[Parameter(Mandatory=$false)]
	[switch]$AllowRebootPassThru = $false,
	[Parameter(Mandatory=$false)]
	[switch]$TerminalServerMode = $false,
	[Parameter(Mandatory=$false)]
	[switch]$DisableLogging = $false
)

Try {
	## Set the script execution policy for this process
	Try { Set-ExecutionPolicy -ExecutionPolicy 'ByPass' -Scope 'Process' -Force -ErrorAction 'Stop' } Catch {}

	##*===============================================
	##* VARIABLE DECLARATION
	##*===============================================
	## Variables: Application
	[string]$appVendor = 'Autodesk'
	[string]$appName = 'Inventor View'
	[string]$appVersion = '2019'
	[string]$appArch = ''
	[string]$appLang = ''
	[string]$appRevision = ''
	[string]$appScriptVersion = '1.0.0'
	[string]$appScriptDate = 'XX/XX/20XX'
	[string]$appScriptAuthor = 'Jason Bergner'
	##*===============================================
	## Variables: Install Titles (Only set here to override defaults set by the toolkit)
	[string]$installName = ''
	[string]$installTitle = 'Autodesk Inventor View 2019'

	##* Do not modify section below
	#region DoNotModify

	## Variables: Exit Code
	[int32]$mainExitCode = 0

	## Variables: Script
	[string]$deployAppScriptFriendlyName = 'Deploy Application'
	[version]$deployAppScriptVersion = [version]'3.8.4'
	[string]$deployAppScriptDate = '26/01/2021'
	[hashtable]$deployAppScriptParameters = $psBoundParameters

	## Variables: Environment
	If (Test-Path -LiteralPath 'variable:HostInvocation') { $InvocationInfo = $HostInvocation } Else { $InvocationInfo = $MyInvocation }
	[string]$scriptDirectory = Split-Path -Path $InvocationInfo.MyCommand.Definition -Parent

	## Dot source the required App Deploy Toolkit Functions
	Try {
		[string]$moduleAppDeployToolkitMain = "$scriptDirectory\AppDeployToolkit\AppDeployToolkitMain.ps1"
		If (-not (Test-Path -LiteralPath $moduleAppDeployToolkitMain -PathType 'Leaf')) { Throw "Module does not exist at the specified location [$moduleAppDeployToolkitMain]." }
		If ($DisableLogging) { . $moduleAppDeployToolkitMain -DisableLogging } Else { . $moduleAppDeployToolkitMain }
	}
	Catch {
		If ($mainExitCode -eq 0){ [int32]$mainExitCode = 60008 }
		Write-Error -Message "Module [$moduleAppDeployToolkitMain] failed to load: `n$($_.Exception.Message)`n `n$($_.InvocationInfo.PositionMessage)" -ErrorAction 'Continue'
		## Exit the script, returning the exit code to SCCM
		If (Test-Path -LiteralPath 'variable:HostInvocation') { $script:ExitCode = $mainExitCode; Exit } Else { Exit $mainExitCode }
	}

	#endregion
	##* Do not modify section above
	##*===============================================
	##* END VARIABLE DECLARATION
	##*===============================================

	If ($deploymentType -ine 'Uninstall' -and $deploymentType -ine 'Repair') {
		##*===============================================
		##* PRE-INSTALLATION
		##*===============================================
		[string]$installPhase = 'Pre-Installation'

		## Show Welcome Message, Close Autodesk Inventor View With a 60 Second Countdown Before Automatically Closing
		Show-InstallationWelcome -CloseApps 'AutodeskDesktopApp,AdAppMgrSvc,InventorView,Ipj' -CloseAppsCountdown 60

		## Show Progress Message (with the default message)
		Show-InstallationProgress
   
		##*===============================================
		##* INSTALLATION
		##*===============================================
		[string]$installPhase = 'Installation'

        If ($ENV:PROCESSOR_ARCHITECTURE -eq 'x86'){
        Write-Log -Message "Detected 32-bit OS Architecture. Autodesk Inventor View 2019 is not supported on 32-bit operating systems." -Severity 1 -Source $deployAppScriptFriendlyName
      
        }
        Else
        {
        Write-Log -Message "Detected 64-bit OS Architecture" -Severity 1 -Source $deployAppScriptFriendlyName

        ## Install Microsoft Visual C++ 2015-2019 Redistributable (x86)
        $ExePath32 = Get-ChildItem -Path "$dirSupportFiles" -Include VC_redist.x86.exe -File -Recurse -ErrorAction SilentlyContinue
        If($ExePath32.Exists)
        {
        Write-Log -Message "Found $($ExePath32.FullName), now attempting to install Microsoft Visual C++ 2015-2019 Redistributable (x86)."
        Show-InstallationProgress "Installing Microsoft Visual C++ 2015-2019 Redistributable (x86). This may take some time. Please wait..."
        Execute-Process -Path "$ExePath32" -Parameters "/install /quiet /norestart /log C:\Windows\Logs\Software\VisualC++2015-2019x86-Install.log" -WindowStyle Hidden
        }

        ## Install Microsoft Visual C++ 2015-2019 Redistributable (x64)
        $ExePath64 = Get-ChildItem -Path "$dirSupportFiles" -Include VC_redist.x64.exe -File -Recurse -ErrorAction SilentlyContinue
        If($ExePath64.Exists)
        {
        Write-Log -Message "Found $($ExePath64.FullName), now attempting to install Microsoft Visual C++ 2015-2019 Redistributable (x64)."
        Show-InstallationProgress "Installing Microsoft Visual C++ 2015-2019 Redistributable (x64). This may take some time. Please wait..."
        Execute-Process -Path "$ExePath64" -Parameters "/install /quiet /norestart /log C:\Windows\Logs\Software\VisualC++2015-2019x64-Install.log" -WindowStyle Hidden
        }

        ## Install Autodesk Inventor View 2019
        Show-InstallationProgress "Installing Autodesk Inventor View 2019. This may take some time. Please wait..."
        Execute-Process -Path "$dirFiles\Setup.exe" -Parameters "/W /Q /I $dirFiles\setup.ini" -WindowStyle Hidden
        }

        ## Remove Autodesk Desktop App Desktop Shortcut (If Present)
        if (Test-Path -Path "$envPublic\Desktop\Autodesk Desktop App.lnk") {
        Write-Log -Message "Removing Autodesk Desktop App Desktop Shortcut."
        Remove-Item -Path "$envPublic\Desktop\Autodesk Desktop App.lnk" -Force -Recurse -ErrorAction SilentlyContinue 
        }

        ## Disable Data Collection and Use (Autodesk Analytics)
        Write-Log -Message "Disabling Data Collection and Use (Autodesk Analytics)."

        [scriptblock]$HKCURegistrySettings = {
        Set-RegistryKey -Key 'HKCU\Software\Autodesk\MC3' -Name 'ADAOptIn' -Value 0 -Type DWord -SID $UserProfile.SID
        Set-RegistryKey -Key 'HKCU\Software\Autodesk\MC3' -Name 'ADARePrompted' -Value 1 -Type DWord -SID $UserProfile.SID
        }
        Invoke-HKCURegistrySettingsForAllUsers -RegistrySettings $HKCURegistrySettings -ErrorAction SilentlyContinue
       
		##*===============================================
		##* POST-INSTALLATION
		##*===============================================
		[string]$installPhase = 'Post-Installation'

	}
	ElseIf ($deploymentType -ieq 'Uninstall')
	{
		##*===============================================
		##* PRE-UNINSTALLATION
		##*===============================================
		[string]$installPhase = 'Pre-Uninstallation'

		## Show Welcome Message, Close Autodesk Inventor View With a 60 Second Countdown Before Automatically Closing
		Show-InstallationWelcome -CloseApps 'AutodeskDesktopApp,AdAppMgrSvc,InventorView,Ipj' -CloseAppsCountdown 60

		## Show Progress Message (with the default message)
		Show-InstallationProgress


		##*===============================================
		##* UNINSTALLATION
		##*===============================================
		[string]$installPhase = 'Uninstallation'

        ## Uninstall Autodesk Inventor View 2019
        Execute-MSI -Action Uninstall -Path '{7F4DD591-2364-0004-0000-7107D70F3DB4}'

        ## Uninstall Autodesk Inventor View 2019 English Language Pack
        Execute-MSI -Action Uninstall -Path '{7F4DD591-2364-0004-1033-7107D70F3DB4}'

        ## Uninstall Autodesk Desktop App
        if (Test-Path -Path "$envProgramFilesX86\Autodesk\Autodesk Desktop App\removeAdAppMgr.exe") {
        Show-InstallationProgress "Uninstalling Autodesk Desktop App. This may take some time. Please wait..."
        Execute-Process -Path "$envProgramFilesX86\Autodesk\Autodesk Desktop App\removeAdAppMgr.exe" -Parameters "--mode unattended" -WindowStyle Hidden
        Sleep -Seconds 5
        }

        ## Cleanup Autodesk Directories
        $Users = Get-ChildItem C:\Users
        foreach ($user in $Users){

        $AutodeskDir1 = "$($user.fullname)\AppData\Local\Autodesk"
        If (Test-Path $AutodeskDir1) {
        Write-Log -Message "Cleanup $AutodeskDir1 Directory."
        Remove-Item -Path $AutodeskDir1 -Force -Recurse -ErrorAction SilentlyContinue
        Sleep -Seconds 5
        }
        $AutodeskDir2 = "$($user.fullname)\AppData\Roaming\Autodesk"
        If (Test-Path $AutodeskDir2) {
        Write-Log -Message "Cleanup $AutodeskDir2 Directory."
        Remove-Item -Path $AutodeskDir2 -Force -Recurse -ErrorAction SilentlyContinue
        Sleep -Seconds 5
        }
        }
        if (Test-Path -Path "$envAllUsersProfile\Autodesk\") {
        Write-Log -Message "Cleanup $envAllUsersProfile\Autodesk\ Directory."
        Remove-Item -Path "$envAllUsersProfile\Autodesk\" -Force -Recurse -ErrorAction SilentlyContinue 
        Sleep -Seconds 5
        }

        ## Uninstall Autodesk Genuine Service
        Stop-Process -Name GenuineService -Force -ErrorAction SilentlyContinue
        Execute-MSI -Action Uninstall -Path '{1C5DB7B1-CE18-438C-B071-3AD6B8ADA5A0}'
        Stop-Process -Name message_router -Force -ErrorAction SilentlyContinue


		##*===============================================
		##* POST-UNINSTALLATION
		##*===============================================
		[string]$installPhase = 'Post-Uninstallation'


	}
	ElseIf ($deploymentType -ieq 'Repair')
	{
		##*===============================================
		##* PRE-REPAIR
		##*===============================================
		[string]$installPhase = 'Pre-Repair'

		## Show Progress Message (with the default message)
		Show-InstallationProgress


		##*===============================================
		##* REPAIR
		##*===============================================
		[string]$installPhase = 'Repair'


		##*===============================================
		##* POST-REPAIR
		##*===============================================
		[string]$installPhase = 'Post-Repair'


    }
	##*===============================================
	##* END SCRIPT BODY
	##*===============================================

	## Call the Exit-Script function to perform final cleanup operations
	Exit-Script -ExitCode $mainExitCode
}
Catch {
	[int32]$mainExitCode = 60001
	[string]$mainErrorMessage = "$(Resolve-Error)"
	Write-Log -Message $mainErrorMessage -Severity 3 -Source $deployAppScriptFriendlyName
	Show-DialogBox -Text $mainErrorMessage -Icon 'Stop'
	Exit-Script -ExitCode $mainExitCode
}

Ok, all the hard work is done and now you can install or uninstall Autodesk Inventor View 2019 using one single PowerShell script. Simply change the DeploymentType parameter to install or uninstall. The script is also configured to Disable the Data Collection and Use (Autodesk Analytics) prompt. Logging functionality is built-in automatically and you can view the log files under “C:\Windows\Logs\Software”.


Autodesk Inventor View 2019 NonInteractive Install (PowerShell)

NonInteractive means Very Silent, i.e. no blocking apps. This is automatically set if it is detected that the process is not running in the user session and it is not possible for anyone to provide input using a mouse or keyboard.

  • Open Windows PowerShell by Right-Clicking on Windows PowerShell and selecting Run as Administrator
  • Change the directory to “C:\Downloads\InventorView2019”
    • PS C:\Downloads\InventorView2019>
  • Enter the following command:
Powershell.exe -ExecutionPolicy Bypass .\Deploy-InventorView2019.ps1 -DeploymentType "Install" -DeployMode "NonInteractive"

Autodesk Inventor View 2019 Silent Install (PowerShell)

Silent means no dialogs (progress and balloon tip notifications are suppressed).

  • Open Windows PowerShell by Right-Clicking on Windows PowerShell and selecting Run as Administrator
  • Change the directory to “C:\Downloads\InventorView2019
    • PS C:\Downloads\InventorView2019>
  • Enter the following command:
Powershell.exe -ExecutionPolicy Bypass .\Deploy-InventorView2019.ps1 -DeploymentType "Install" -DeployMode "Silent"

Autodesk Inventor View 2019 Interactive Install (PowerShell)

Interactive means the install will show dialogs including progress and balloon tip notifications.

  • Open Windows PowerShell by Right-Clicking on Windows PowerShell and selecting Run as Administrator
  • Change the directory to “C:\Downloads\InventorView2019”
    • PS C:\Downloads\InventorView2019>
  • Enter the following command:
Powershell.exe -ExecutionPolicy Bypass .\Deploy-InventorView2019.ps1 -DeploymentType "Install" -DeployMode "Interactive"

How to Uninstall Autodesk Inventor View 2019 Using the PowerShell App Deployment Toolkit

Autodesk Inventor View 2019 NonInteractive Uninstall (PowerShell)

NonInteractive means Very Silent, i.e. no blocking apps. This is automatically set if it is detected that the process is not running in the user session and it is not possible for anyone to provide input using a mouse or keyboard.

  • Open Windows PowerShell by Right-Clicking on Windows PowerShell and selecting Run as Administrator
  • Change the directory to “C:\Downloads\InventorView2019
    • PS C:\Downloads\InventorView2019>
  • Enter the following command:
Powershell.exe -ExecutionPolicy Bypass .\Deploy-InventorView2019.ps1 -DeploymentType "Uninstall" -DeployMode "NonInteractive"

Autodesk Inventor View 2019 Silent Uninstall (PowerShell)

Silent means no dialogs (progress and balloon tip notifications are suppressed).

  • Open Windows PowerShell by Right-Clicking on Windows PowerShell and selecting Run as Administrator
  • Change the directory to “C:\Downloads\InventorView2019
    • PS C:\Downloads\InventorView2019>
  • Enter the following command:
Powershell.exe -ExecutionPolicy Bypass .\Deploy-InventorView2019.ps1 -DeploymentType "Uninstall" -DeployMode "Silent"

Autodesk Inventor View 2019 Interactive Uninstall (PowerShell)

Interactive means the install will show dialogs including progress and balloon tip notifications.

  • Open Windows PowerShell by Right-Clicking on Windows PowerShell and selecting Run as Administrator
  • Change the directory to “C:\Downloads\InventorView2019
    • PS C:\Downloads\InventorView2019>
  • Enter the following command:
Powershell.exe -ExecutionPolicy Bypass .\Deploy-InventorView2019.ps1 -DeploymentType "Uninstall" -DeployMode "Interactive"

Always make sure to test everything in a development environment prior to implementing anything into production. The information in this article is provided “As Is” without warranty of any kind.

Jason Bergner

I am an accomplished Software Engineer at Patch My PC, leveraging more than 18 years of hands-on experience in Configuration Manager administration and application packaging. I am driven by a genuine passion for solving complex problems and consistently strive to discover innovative and effective solutions. Sharing my extensive knowledge of application deployments is a true joy for me, and I am honored to contribute to the community here at Silent Install HQ.

Recent Posts