Microsoft Endpoint Manager Configuration Manager (MEMCM / SCCM) and Microsoft Intune use Detection Rules to determine the presence of Applications & Win32 Apps. The detection rules ensure that application installations only begin to run if the application is not already installed on the device. This article will serve as an informative guide and give you a clear understanding of how to create an updated custom detection script for each new version of CAD Reader using PowerShell.
How to Create a Custom Detection Script for CAD Reader
CAD Reader (File Detection Method)
- Install the version of CAD Reader you want to deploy on a test box or VM
- Check out the following posts for further details
- Open Windows PowerShell ISE by Right-Clicking on Windows PowerShell ISE and selecting Run as Administrator
- Copy the following code into the Windows PowerShell ISE
## Check for CAD Reader (File Detection Method) $CADReaderExe = (Get-ChildItem -Path "C:\Program Files\CADReader*\CADReader.exe","C:\Program Files (x86)\CADReader*\CADReader.exe" -ErrorAction SilentlyContinue) $CADReaderExe.FullName $CADReaderPath = $($CADReaderExe.FullName).Replace("C:\Program Files\","").Replace("C:\Program Files (x86)\","") $FileVersion = (Get-Item -Path "$($CADReaderExe.FullName)" -ErrorAction SilentlyContinue).VersionInfo.FileVersion ## Create Text File with CAD Reader File Detection Method $FilePath = "C:\Windows\Temp\CAD_Reader_Detection_Method.txt" New-Item -Path "$FilePath" -Force Set-Content -Path "$FilePath" -Value "If([String](Get-Item -Path `"`$Env:ProgramFiles\$CADReaderPath`",`"`${Env:ProgramFiles(x86)}\$CADReaderPath`" -ErrorAction SilentlyContinue).VersionInfo.FileVersion -ge `"$FileVersion`"){" Add-Content -Path "$FilePath" -Value "Write-Host `"Installed`"" Add-Content -Path "$FilePath" -Value "Exit 0" Add-Content -Path "$FilePath" -Value "}" Add-Content -Path "$FilePath" -Value "else {" Add-Content -Path "$FilePath" -Value "Exit 1" Add-Content -Path "$FilePath" -Value "}" Invoke-Item $FilePath
- Click Run Script (F5)
- A text file will open with the CAD Reader Detection Method script required to detect the current version of CAD Reader that is installed on the device you are running the script from.
Example:
If([String](Get-Item -Path "$Env:ProgramFiles\CADReaderInternational\CADReader.exe","${Env:ProgramFiles(x86)}\CADReaderInternational\CADReader.exe" -ErrorAction SilentlyContinue).VersionInfo.FileVersion -ge "3.5.2.15"){ Write-Host "Installed" Exit 0 } else { Exit 1 }
- Copy the CAD Reader Detection Method script content into the Custom Detection Rules (Script)
- Microsoft Endpoint Manager Configuration Manager (MEMCM / SCCM)
- Microsoft Intune
Always make sure to test everything in a development environment prior to implementing anything into production. The information in this article is provided “As Is” without warranty of any kind.