This article will serve as an informative guide and give you a clear understanding of how to perform silent or interactive installs and uninstalls of Autodesk Navisworks Simulate 2024 using the Powershell App Deployment Toolkit. The PowerShell App Deployment Toolkit can be used to replace your WiseScript, VBScript and Batch wrapper scripts with one versatile, re-usable and extensible tool. This tool is an absolute must for Microsoft Endpoint Manager Configuration Manager (MEMCM) / (SCCM) Administrators or anyone who is responsible for packaging and deploying software.
How to Install Autodesk Navisworks Simulate 2024 Using the PowerShell App Deployment Toolkit
- Download the Powershell App Deployment Toolkit 3.8.4:
- Download the zip file to a folder created at (C:\Downloads)
- Open Windows PowerShell by Right-Clicking on Windows PowerShell and selecting Run as Administrator
- Enter the following command to remove the Zone.Identifier:
Unblock-File -Path C:\Downloads\PSAppDeployToolkit_v3.8.4.zip
- Enter the following command to extract the contents of the zip file:
Expand-Archive -Path C:\Downloads\PSAppDeployToolkit_v3.8.4.zip -DestinationPath C:\Downloads\PADT
- Enter the following commands to copy the AppDeployToolkit & Files folders to “C:\Downloads\NavisworksSimulate2024”:
Copy-Item -Path "C:\Downloads\PADT\Toolkit\AppDeployToolkit" -Destination "C:\Downloads\NavisworksSimulate2024\AppDeployToolkit" -Recurse
Copy-Item -Path "C:\Downloads\PADT\Toolkit\Files" -Destination "C:\Downloads\NavisworksSimulate2024\Files"
You should now see the AppDeploymentToolkit folder with files & the empty Files folder at “C:\Downloads\NavisworksSimulate2024”
- Sign in to Autodesk Account at: http://manage.autodesk.com
- Click All Products & Services on the Home page menu
- Click the download icon next to the product name
- If you don’t own a Navisworks Simulate license, you can download a trial version to test. See the Autodesk Navisworks Simulate 2024 Silent Install (How-To Guide) for details.
- Download the EXE’s to C:\Downloads
- Enter the following command to Extract the contents of the EXE’s:
Autodesk_Navisworks_Simulate_2024_Win_64bit_dlm_001_002.sfx.exe -suppresslaunch -d "C:\Downloads"
- Copy the contents of the extracted folder to “C:\Downloads\NavisworksSimulate2024\Files\”
- You should now see a similar structure inside the Files directory
- 3rd Party
- Content
- manifest
- ODIS
- SetupRes
- x64
- x86
- dlm.ini
- Setup.exe
- Setup.exe.config
- setup.xml
- upi_list.json
- You should now see a similar structure inside the Files directory
- Open Notepad or your favorite text editor
- Add the following lines:
{
"lastUpdated": 1234123412341,
"preferences": [
{
"consentId": "ADSK_PUD_CONTRACTUAL_NECESSITY_DESKTOP",
"optIn": false
},
{
"consentId": "ADSK_PUD_OPTIMIZATION_IMPROVEMENT_DESKTOP",
"optIn": false
},
{
"consentId": "ADSK_PUD_GO_TO_MARKET_DESKTOP",
"optIn": false
}
],
"userActionRequired": false,
"userId": "UnNamed"
}
- Save the file to “C:\Downloads\NavisworksSimulate2024\Files\” and name it: UnNamed.json
- Copy the PowerShell script below to “C:\Downloads\NavisworksSimulate2024” & name it Deploy-NavisworksSimulate2024.ps1
<# .SYNOPSIS This script performs the installation or uninstallation of Autodesk Navisworks Simulate 2024. # LICENSE # PowerShell App Deployment Toolkit - Provides a set of functions to perform common application deployment tasks on Windows. Copyright (C) 2017 - Sean Lillis, Dan Cunningham, Muhammad Mashwani, Aman Motazedian. This program is free software: you can redistribute it and/or modify it under the terms of the GNU Lesser General Public License as published by the Free Software Foundation, either version 3 of the License, or any later version. This program is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for more details. You should have received a copy of the GNU Lesser General Public License along with this program. If not, see <http://www.gnu.org/licenses/>. .DESCRIPTION The script is provided as a template to perform an install or uninstall of an application(s). The script either performs an "Install" deployment type or an "Uninstall" deployment type. The install deployment type is broken down into 3 main sections/phases: Pre-Install, Install, and Post-Install. The script dot-sources the AppDeployToolkitMain.ps1 script which contains the logic and functions required to install or uninstall an application. .PARAMETER DeploymentType The type of deployment to perform. Default is: Install. .PARAMETER DeployMode Specifies whether the installation should be run in Interactive, Silent, or NonInteractive mode. Default is: Interactive. Options: Interactive = Shows dialogs, Silent = No dialogs, NonInteractive = Very silent, i.e. no blocking apps. NonInteractive mode is automatically set if it is detected that the process is not user interactive. .PARAMETER AllowRebootPassThru Allows the 3010 return code (requires restart) to be passed back to the parent process (e.g. SCCM) if detected from an installation. If 3010 is passed back to SCCM, a reboot prompt will be triggered. .PARAMETER TerminalServerMode Changes to "user install mode" and back to "user execute mode" for installing/uninstalling applications for Remote Destkop Session Hosts/Citrix servers. .PARAMETER DisableLogging Disables logging to file for the script. Default is: $false. .EXAMPLE PowerShell.exe .\Deploy-NavisworksSimulate2024.ps1 -DeploymentType "Install" -DeployMode "NonInteractive" .EXAMPLE PowerShell.exe .\Deploy-NavisworksSimulate2024.ps1 -DeploymentType "Install" -DeployMode "Silent" .EXAMPLE PowerShell.exe .\Deploy-NavisworksSimulate2024.ps1 -DeploymentType "Install" -DeployMode "Interactive" .EXAMPLE PowerShell.exe .\Deploy-NavisworksSimulate2024.ps1 -DeploymentType "Uninstall" -DeployMode "NonInteractive" .EXAMPLE PowerShell.exe .\Deploy-NavisworksSimulate2024.ps1 -DeploymentType "Uninstall" -DeployMode "Silent" .EXAMPLE PowerShell.exe .\Deploy-NavisworksSimulate2024.ps1 -DeploymentType "Uninstall" -DeployMode "Interactive" .NOTES Toolkit Exit Code Ranges: 60000 - 68999: Reserved for built-in exit codes in Deploy-Application.ps1, Deploy-Application.exe, and AppDeployToolkitMain.ps1 69000 - 69999: Recommended for user customized exit codes in Deploy-Application.ps1 70000 - 79999: Recommended for user customized exit codes in AppDeployToolkitExtensions.ps1 .LINK http://psappdeploytoolkit.com #> [CmdletBinding()] Param ( [Parameter(Mandatory=$false)] [ValidateSet('Install','Uninstall','Repair')] [string]$DeploymentType = 'Install', [Parameter(Mandatory=$false)] [ValidateSet('Interactive','Silent','NonInteractive')] [string]$DeployMode = 'Interactive', [Parameter(Mandatory=$false)] [switch]$AllowRebootPassThru = $false, [Parameter(Mandatory=$false)] [switch]$TerminalServerMode = $false, [Parameter(Mandatory=$false)] [switch]$DisableLogging = $false ) Try { ## Set the script execution policy for this process Try { Set-ExecutionPolicy -ExecutionPolicy 'ByPass' -Scope 'Process' -Force -ErrorAction 'Stop' } Catch {} ##*=============================================== ##* VARIABLE DECLARATION ##*=============================================== ## Variables: Application [string]$appVendor = 'Autodesk' [string]$appName = 'Navisworks Simulate' [string]$appVersion = '2024' [string]$appArch = '' [string]$appLang = '' [string]$appRevision = '' [string]$appScriptVersion = '1.0.0' [string]$appScriptDate = 'XX/XX/20XX' [string]$appScriptAuthor = 'Jason Bergner' ##*=============================================== ## Variables: Install Titles (Only set here to override defaults set by the toolkit) [string]$installName = '' [string]$installTitle = 'Autodesk Navisworks Simulate 2024' ##* Do not modify section below #region DoNotModify ## Variables: Exit Code [int32]$mainExitCode = 0 ## Variables: Script [string]$deployAppScriptFriendlyName = 'Deploy Application' [version]$deployAppScriptVersion = [version]'3.8.4' [string]$deployAppScriptDate = '26/01/2021' [hashtable]$deployAppScriptParameters = $psBoundParameters ## Variables: Environment If (Test-Path -LiteralPath 'variable:HostInvocation') { $InvocationInfo = $HostInvocation } Else { $InvocationInfo = $MyInvocation } [string]$scriptDirectory = Split-Path -Path $InvocationInfo.MyCommand.Definition -Parent ## Dot source the required App Deploy Toolkit Functions Try { [string]$moduleAppDeployToolkitMain = "$scriptDirectory\AppDeployToolkit\AppDeployToolkitMain.ps1" If (-not (Test-Path -LiteralPath $moduleAppDeployToolkitMain -PathType 'Leaf')) { Throw "Module does not exist at the specified location [$moduleAppDeployToolkitMain]." } If ($DisableLogging) { . $moduleAppDeployToolkitMain -DisableLogging } Else { . $moduleAppDeployToolkitMain } } Catch { If ($mainExitCode -eq 0){ [int32]$mainExitCode = 60008 } Write-Error -Message "Module [$moduleAppDeployToolkitMain] failed to load: `n$($_.Exception.Message)`n `n$($_.InvocationInfo.PositionMessage)" -ErrorAction 'Continue' ## Exit the script, returning the exit code to SCCM If (Test-Path -LiteralPath 'variable:HostInvocation') { $script:ExitCode = $mainExitCode; Exit } Else { Exit $mainExitCode } } #endregion ##* Do not modify section above ##*=============================================== ##* END VARIABLE DECLARATION ##*=============================================== If ($deploymentType -ine 'Uninstall' -and $deploymentType -ine 'Repair') { ##*=============================================== ##* PRE-INSTALLATION ##*=============================================== [string]$installPhase = 'Pre-Installation' ## Microsoft Intune Win32 App Workaround - Check If Running 32-bit Powershell on 64-bit OS, Restart as 64-bit Process If (!([Environment]::Is64BitProcess)){ If([Environment]::Is64BitOperatingSystem){ Write-Log -Message "Running 32-bit Powershell on 64-bit OS, Restarting as 64-bit Process..." -Severity 2 $Arguments = "-NoProfile -ExecutionPolicy ByPass -WindowStyle Hidden -File `"" + $myinvocation.mycommand.definition + "`"" $Path = (Join-Path $Env:SystemRoot -ChildPath "\sysnative\WindowsPowerShell\v1.0\powershell.exe") Start-Process $Path -ArgumentList $Arguments -Wait Write-Log -Message "Finished Running x64 version of PowerShell" Exit }Else{ Write-Log -Message "Running 32-bit Powershell on 32-bit OS" } } ## Show Welcome Message, Close Autodesk Navisworks Simulate With a 60 Second Countdown Before Automatically Closing Show-InstallationWelcome -CloseApps 'AcEventSync,AcQMod,Autodesk Access UI Host,AdskAccessCore,AdskIdentityManager,ADPClientService,AdskLicensingService,AdskLicensingAgent,FNPLicensingService64,OptionsEditor,Roamer' -CloseAppsCountdown 60 ## Show Progress Message (with the default message) Show-InstallationProgress ##*=============================================== ##* INSTALLATION ##*=============================================== [string]$installPhase = 'Installation' If ($ENV:PROCESSOR_ARCHITECTURE -eq 'x86'){ Write-Log -Message "Detected 32-bit OS Architecture. Autodesk Navisworks Simulate 2024 is not supported on 32-bit operating systems." -Severity 1 -Source $deployAppScriptFriendlyName } Else { Write-Log -Message "Detected 64-bit OS Architecture" -Severity 1 -Source $deployAppScriptFriendlyName ## Install Autodesk Navisworks Simulate 2024 Show-InstallationProgress "Installing Autodesk Navisworks Simulate 2024. This may take some time. Please wait..." Execute-Process -Path "$dirFiles\Setup.exe" -Parameters "-q" -WindowStyle Hidden ## Remove Navisworks Simulate 2024 Desktop Shortcut (If Present) If (Test-Path -Path "$envPublic\Desktop\Navisworks Simulate 2024*.lnk") { Write-Log -Message "Removing Navisworks Simulate 2024 Desktop Shortcut." Remove-Item -Path "$envPublic\Desktop\Navisworks Simulate 2024*.lnk" -Force -Recurse -ErrorAction SilentlyContinue } ## Suppress Privacy Settings Pop-up $JSON = Get-ChildItem -Path "$dirFiles" -Include UnNamed.json -File -Recurse -ErrorAction SilentlyContinue If($JSON.Exists) { Write-Log -Message "Copying UnNamed.json To User Profile (Suppress Privacy Settings Pop-up)" $UserProfiles = Get-WmiObject Win32_UserProfile | Where {(!$_.Special) -and $_.LocalPath -notlike 'C:\Windows\ServiceProfiles*'} | Select-Object -ExpandProperty LocalPath ForEach ($Profile in $UserProfiles) { New-Item "$Profile\AppData\Roaming\Autodesk\ADPSDK\UserConsent\" -ItemType Directory -Force Copy-Item $JSON -Destination "$Profile\AppData\Roaming\Autodesk\ADPSDK\UserConsent\" -ErrorAction SilentlyContinue } } } ##*=============================================== ##* POST-INSTALLATION ##*=============================================== [string]$installPhase = 'Post-Installation' } ElseIf ($deploymentType -ieq 'Uninstall') { ##*=============================================== ##* PRE-UNINSTALLATION ##*=============================================== [string]$installPhase = 'Pre-Uninstallation' ## Disable Autodesk Licensing Service Set-Service -Name 'AdskLicensingService' -StartupType 'Disabled' -ErrorAction SilentlyContinue ## Disable FlexNet Licensing Service Set-Service -Name 'FlexNet Licensing Service 64' -StartupType 'Disabled' -ErrorAction SilentlyContinue ## Show Welcome Message, Close Autodesk Navisworks Simulate With a 60 Second Countdown Before Automatically Closing Show-InstallationWelcome -CloseApps 'AcEventSync,AcQMod,Autodesk Access UI Host,AdskAccessCore,AdskIdentityManager,ADPClientService,AdskLicensingService,AdskLicensingAgent,FNPLicensingService64,OptionsEditor,Roamer' -CloseAppsCountdown 60 ## Show Progress Message (with the default message) Show-InstallationProgress -StatusMessage "Uninstalling $installTitle. Please Wait..." ##*=============================================== ##* UNINSTALLATION ##*=============================================== [string]$installPhase = 'Uninstallation' ## Uninstall Autodesk Licensing If (Test-Path -Path "$envProgramFilesX86\Common Files\Autodesk Shared\AdskLicensing\uninstall.exe") { Write-Log -Message "Uninstalling Autodesk Licensing." Execute-Process -Path "$envProgramFilesX86\Common Files\Autodesk Shared\AdskLicensing\uninstall.exe" -Parameters "--mode unattended" -WindowStyle Hidden Start-Sleep -Seconds 5 } ## Uninstall Autodesk Navisworks Simulate 2024 $AppList = Get-InstalledApplication -Name 'Autodesk Navisworks Simulate 2024' -Exact ForEach ($App in $AppList) { If($App.UninstallString) { $GUID = Get-ChildItem -Path "HKLM:\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall" | Get-ItemProperty | Where-Object {$_.DisplayName -match 'Autodesk Navisworks Simulate 2024' -and $_.UninstallString -like '*Installer.exe*' } | Select-Object -Property PSChildName Write-Log -Message "Found $($App.DisplayName) $($App.DisplayVersion) and a valid uninstall string, now attempting to uninstall." If (Test-Path -Path "$envProgramFiles\Autodesk\AdODIS\V1\Installer.exe") { Execute-Process -Path "$envProgramFiles\Autodesk\AdODIS\V1\Installer.exe" -Parameters "-i uninstall -q -m C:\ProgramData\Autodesk\ODIS\metadata\$($GUID.PSChildName)\bundleManifest.xml" -WindowStyle Hidden -IgnoreExitCodes "8,1603" Start-Sleep -Seconds 5 } } } ## Uninstall Microsoft SQL Server 2019 LocalDB Remove-MSIApplications "Microsoft SQL Server 2019 LocalDB" $AppList = Get-InstalledApplication -Name 'Microsoft SQL Server 2019 LocalDB' ForEach ($App in $AppList) { If($App.UninstallString) { $GUID = $($App.UninstallString).Replace('MsiExec.exe /I','').Replace('MsiExec.exe /X','') Write-Log -Message "Found $($App.DisplayName) $($App.DisplayVersion) and a valid uninstall string, now attempting to uninstall." Execute-ProcessAsUser -Path "$exeMsiexec" -Parameters "/x $GUID REBOOT=ReallySuppress /qn /L*v ""$configToolkitLogDir\Microsoft_SQL_Server_2019_LocalDB-Uninstall.log""" -Wait Start-Sleep -Seconds 5 } } ## Uninstall Autodesk Access (Autodesk Identity Manager) $AppList = Get-InstalledApplication -Name 'Autodesk Identity Manager' ForEach ($App in $AppList) { If($App.UninstallString) { $UninstPath = $($App.UninstallString).Replace('"','') If(Test-Path -Path $UninstPath) { Write-Log -Message "Found $($App.DisplayName) $($App.DisplayVersion) and a valid uninstall string, now attempting to uninstall." Execute-Process -Path $UninstPath -Parameters "--mode unattended" -WindowStyle Hidden Start-Sleep -Seconds 5 If(Test-Path -Path "$envProgramFiles\Autodesk\AdODIS\V1\RemoveODIS.exe") { Execute-Process -Path "$envProgramFiles\Autodesk\AdODIS\V1\RemoveODIS.exe" -Parameters "--mode unattended" -WindowStyle Hidden Start-Sleep -Seconds 5 } } } } ## Cleanup Autodesk Directories $Users = Get-ChildItem C:\Users foreach ($user in $Users){ $AutodeskLocal = "$($user.fullname)\AppData\Local\Autodesk" If (Test-Path $AutodeskLocal) { Write-Log -Message "Cleanup $AutodeskLocal Directory." Remove-Item -Path $AutodeskLocal -Force -Recurse -ErrorAction SilentlyContinue Start-Sleep -Seconds 5 } $AutodeskRoaming = "$($user.fullname)\AppData\Roaming\Autodesk" If (Test-Path $AutodeskRoaming) { Write-Log -Message "Cleanup $AutodeskRoaming Directory." Remove-Item -Path $AutodeskRoaming -Force -Recurse -ErrorAction SilentlyContinue Start-Sleep -Seconds 5 } } If (Test-Path -Path "$envAllUsersProfile\Autodesk\") { Write-Log -Message "Cleanup $envAllUsersProfile\Autodesk\ Directory." Remove-Item -Path "$envAllUsersProfile\Autodesk\" -Force -Recurse -ErrorAction SilentlyContinue Start-Sleep -Seconds 5 } ## Uninstall Autodesk Genuine Service Stop-Process -Name GenuineService -Force -ErrorAction SilentlyContinue Remove-MSIApplications "Autodesk Genuine Service" $AppList = Get-InstalledApplication -Name 'Autodesk Genuine Service' ForEach ($App in $AppList) { If($App.UninstallString) { $GUID = $($App.UninstallString).Replace('MsiExec.exe /I','').Replace('MsiExec.exe /X','') Write-Log -Message "Found $($App.DisplayName) $($App.DisplayVersion) and a valid uninstall string, now attempting to uninstall." Execute-ProcessAsUser -Path "$exeMsiexec" -Parameters "/x $GUID REBOOT=ReallySuppress /qn /L*v ""$configToolkitLogDir\Autodesk_Genuine_Service-Uninstall.log""" -Wait Start-Sleep -Seconds 5 } } ##*=============================================== ##* POST-UNINSTALLATION ##*=============================================== [string]$installPhase = 'Post-Uninstallation' } ElseIf ($deploymentType -ieq 'Repair') { ##*=============================================== ##* PRE-REPAIR ##*=============================================== [string]$installPhase = 'Pre-Repair' ##*=============================================== ##* REPAIR ##*=============================================== [string]$installPhase = 'Repair' ##*=============================================== ##* POST-REPAIR ##*=============================================== [string]$installPhase = 'Post-Repair' } ##*=============================================== ##* END SCRIPT BODY ##*=============================================== ## Call the Exit-Script function to perform final cleanup operations Exit-Script -ExitCode $mainExitCode } Catch { [int32]$mainExitCode = 60001 [string]$mainErrorMessage = "$(Resolve-Error)" Write-Log -Message $mainErrorMessage -Severity 3 -Source $deployAppScriptFriendlyName Show-DialogBox -Text $mainErrorMessage -Icon 'Stop' Exit-Script -ExitCode $mainExitCode }
Ok, all the hard work is done and now you can install or uninstall Autodesk Navisworks Simulate 2024 using one single PowerShell script. Simply change the DeploymentType parameter to install or uninstall. Logging functionality is built-in automatically and you can view the log files under “C:\Windows\Logs\Software”.
Autodesk Navisworks Simulate 2024 NonInteractive Install (PowerShell)
NonInteractive means Very Silent, i.e. no blocking apps. This is automatically set if it is detected that the process is not running in the user session and it is not possible for anyone to provide input using a mouse or keyboard.
- Open Windows PowerShell by Right-Clicking on Windows PowerShell and selecting Run as Administrator
- Change the directory to “C:\Downloads\NavisworksSimulate2024”
- PS C:\Downloads\NavisworksSimulate2024>
- Enter the following command:
Powershell.exe -ExecutionPolicy Bypass .\Deploy-NavisworksSimulate2024.ps1 -DeploymentType "Install" -DeployMode "NonInteractive"
Autodesk Navisworks Simulate 2024 Silent Install (PowerShell)
Silent means no dialogs (progress and balloon tip notifications are suppressed).
- Open Windows PowerShell by Right-Clicking on Windows PowerShell and selecting Run as Administrator
- Change the directory to “C:\Downloads\NavisworksSimulate2024“
- PS C:\Downloads\NavisworksSimulate2024>
- Enter the following command:
Powershell.exe -ExecutionPolicy Bypass .\Deploy-NavisworksSimulate2024.ps1 -DeploymentType "Install" -DeployMode "Silent"
Autodesk Navisworks Simulate 2024 Interactive Install (PowerShell)
Interactive means the install will show dialogs including progress and balloon tip notifications.
- Open Windows PowerShell by Right-Clicking on Windows PowerShell and selecting Run as Administrator
- Change the directory to “C:\Downloads\NavisworksSimulate2024”
- PS C:\Downloads\NavisworksSimulate2024>
- Enter the following command:
Powershell.exe -ExecutionPolicy Bypass .\Deploy-NavisworksSimulate2024.ps1 -DeploymentType "Install" -DeployMode "Interactive"
How to Uninstall Autodesk Navisworks Simulate 2024 Using the PowerShell App Deployment Toolkit
Autodesk Navisworks Simulate 2024 NonInteractive Uninstall (PowerShell)
NonInteractive means Very Silent, i.e. no blocking apps. This is automatically set if it is detected that the process is not running in the user session and it is not possible for anyone to provide input using a mouse or keyboard.
- Open Windows PowerShell by Right-Clicking on Windows PowerShell and selecting Run as Administrator
- Change the directory to “C:\Downloads\NavisworksSimulate2024“
- PS C:\Downloads\NavisworksSimulate2024>
- Enter the following command:
Powershell.exe -ExecutionPolicy Bypass .\Deploy-NavisworksSimulate2024.ps1 -DeploymentType "Uninstall" -DeployMode "NonInteractive"
Autodesk Navisworks Simulate 2024 Silent Uninstall (PowerShell)
Silent means no dialogs (progress and balloon tip notifications are suppressed).
- Open Windows PowerShell by Right-Clicking on Windows PowerShell and selecting Run as Administrator
- Change the directory to “C:\Downloads\NavisworksSimulate2024“
- PS C:\Downloads\NavisworksSimulate2024>
- Enter the following command:
Powershell.exe -ExecutionPolicy Bypass .\Deploy-NavisworksSimulate2024.ps1 -DeploymentType "Uninstall" -DeployMode "Silent"
Autodesk Navisworks Simulate 2024 Interactive Uninstall (PowerShell)
Interactive means the install will show dialogs including progress and balloon tip notifications.
- Open Windows PowerShell by Right-Clicking on Windows PowerShell and selecting Run as Administrator
- Change the directory to “C:\Downloads\NavisworksSimulate2024“
- PS C:\Downloads\NavisworksSimulate2024>
- Enter the following command:
Powershell.exe -ExecutionPolicy Bypass .\Deploy-NavisworksSimulate2024.ps1 -DeploymentType "Uninstall" -DeployMode "Interactive"
Always make sure to test everything in a development environment prior to implementing anything into production. The information in this article is provided “As Is” without warranty of any kind.