Microsoft Endpoint Manager Configuration Manager (MEMCM / SCCM) and Microsoft Intune use Detection Rules to determine the presence of Applications & Win32 Apps. The detection rules ensure that application installations only begin to run if the application is not already installed on the device. This article will serve as an informative guide and give you a clear understanding of how to create an updated custom detection script for each new version of Lenovo System Update using PowerShell.
How to Create a Custom Detection Script for Lenovo System Update
Lenovo System Update (File Detection Method)
- Install the version of Lenovo System Update you want to deploy on a test box or VM
- Check out the following posts for further details
- Open Windows PowerShell ISE by Right-Clicking on Windows PowerShell ISE and selecting Run as Administrator
- Copy the following code into the Windows PowerShell ISE
## Check for Lenovo System Update (File Detection Method) $LenovoSUExe = (Get-ChildItem -Path "C:\Program Files\Lenovo\System Update\tvsu.exe","C:\Program Files (x86)\Lenovo\System Update\tvsu.exe" -ErrorAction SilentlyContinue) $LenovoSUExe.FullName $LenovoSUPath = $($LenovoSUExe.FullName).Replace("C:\Program Files\","").Replace("C:\Program Files (x86)\","") $FileVersion = (Get-Item -Path "$($LenovoSUExe.FullName)" -ErrorAction SilentlyContinue).VersionInfo.FileVersionRaw ## Create Text File with Lenovo System Update File Detection Method $FilePath = "C:\Windows\Temp\Lenovo_System_Update_Detection_Method.txt" New-Item -Path "$FilePath" -Force Set-Content -Path "$FilePath" -Value "If([String](Get-Item -Path `"`$Env:ProgramFiles\$LenovoSUPath`",`"`${Env:ProgramFiles(x86)}\$LenovoSUPath`" -ErrorAction SilentlyContinue).VersionInfo.FileVersionRaw -ge `"$FileVersion`"){" Add-Content -Path "$FilePath" -Value "Write-Host `"Installed`"" Add-Content -Path "$FilePath" -Value "Exit 0" Add-Content -Path "$FilePath" -Value "}" Add-Content -Path "$FilePath" -Value "else {" Add-Content -Path "$FilePath" -Value "Exit 1" Add-Content -Path "$FilePath" -Value "}" Invoke-Item $FilePath
- Click Run Script (F5)
- A text file will open with the Lenovo System Update Detection Method script required to detect the current version of Lenovo System Update that is installed on the device you are running the script from.
Example:
If([String](Get-Item -Path "$Env:ProgramFiles\Lenovo\System Update\tvsu.exe","${Env:ProgramFiles(x86)}\Lenovo\System Update\tvsu.exe" -ErrorAction SilentlyContinue).VersionInfo.FileVersionRaw -ge "5.7.0.140"){ Write-Host "Installed" Exit 0 } else { Exit 1 }
- Copy the Lenovo System Update Detection Method script content into the Custom Detection Rules (Script)
- Microsoft Endpoint Manager Configuration Manager (MEMCM / SCCM)
- Microsoft Intune
Lenovo System Update (Registry Detection Method)
- Install the version of Lenovo System Update you want to deploy on a test box or VM
- Check out the following posts for further details
- Open Windows PowerShell ISE by Right-Clicking on Windows PowerShell ISE and selecting Run as Administrator
- Copy the following code into the Windows PowerShell ISE
## Check for Lenovo System Update (Registry Detection Method) $LenovoSU = Get-ChildItem -Path "HKLM:\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall","HKLM:\SOFTWARE\Wow6432Node\Microsoft\Windows\CurrentVersion\Uninstall" | Get-ItemProperty | Where-Object {$_.DisplayName -match 'Lenovo System Update' } | Select-Object -Property DisplayName, DisplayVersion, PSChildName $LenovoSU.DisplayVersion $LenovoSU.PSChildName ## Create Text File with Lenovo System Update Registry Detection Method $FilePath = "C:\Windows\Temp\Lenovo_System_Update_Detection_Method.txt" New-Item -Path "$FilePath" -Force Set-Content -Path "$FilePath" -Value "If([Version](Get-ItemPropertyValue -Path 'HKLM:\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall\$($LenovoSU.PSChildName)','HKLM:\SOFTWARE\WOW6432Node\Microsoft\Windows\CurrentVersion\Uninstall\$($LenovoSU.PSChildName)' -Name DisplayVersion -ea SilentlyContinue) -ge '$($LenovoSU.DisplayVersion)') {" Add-Content -Path "$FilePath" -Value "Write-Host `"Installed`"" Add-Content -Path "$FilePath" -Value "Exit 0" Add-Content -Path "$FilePath" -Value "}" Add-Content -Path "$FilePath" -Value "else {" Add-Content -Path "$FilePath" -Value "Exit 1" Add-Content -Path "$FilePath" -Value "}" Invoke-Item $FilePath
- Click Run Script (F5)
- A text file will open with the Lenovo System Update Detection Method script required to detect the current version of Lenovo System Update that is installed on the device you are running the script from.
Example:
If([Version](Get-ItemPropertyValue -Path 'HKLM:\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall\TVSU_is1','HKLM:\SOFTWARE\WOW6432Node\Microsoft\Windows\CurrentVersion\Uninstall\TVSU_is1' -Name DisplayVersion -ea SilentlyContinue) -ge '5.07.0140') { Write-Host "Installed" Exit 0 } else { Exit 1 }
- Copy the Lenovo System Update Detection Method script content into the Custom Detection Rules (Script)
- Microsoft Endpoint Manager Configuration Manager (MEMCM / SCCM)
- Microsoft Intune
Always make sure to test everything in a development environment prior to implementing anything into production. The information in this article is provided “As Is” without warranty of any kind.