Microsoft Endpoint Manager Configuration Manager (MEMCM / SCCM) and Microsoft Intune use Detection Rules to determine the presence of Applications & Win32 Apps. The detection rules ensure that application installations only begin to run if the application is not already installed on the device. This article will serve as an informative guide and give you a clear understanding of how to create an updated custom detection script for each new version of Autodesk DWG TrueView 2021 using PowerShell.
How to Create a Custom Detection Script for Autodesk DWG TrueView 2021
Autodesk DWG TrueView 2021 (File Detection Method)
- Install the version of Autodesk DWG TrueView 2021 you want to deploy on a test box or VM
- Check out the following posts for further details
- Open Windows PowerShell ISE by Right-Clicking on Windows PowerShell ISE and selecting Run as Administrator
- Copy the following code into the Windows PowerShell ISE
## Check for Autodesk DWG TrueView 2021 (File Detection Method) $DWGTrueViewExe = (Get-ChildItem -Path "C:\Program Files\Autodesk\DWG TrueView 2021*\dwgviewr.exe" -ErrorAction SilentlyContinue) $DWGTrueViewExe.FullName $DWGTrueViewPath = $($DWGTrueViewExe.FullName).Replace("C:\Program Files\","") $ProductVersion = (Get-Item -Path "$($DWGTrueViewExe.FullName)" -ErrorAction SilentlyContinue).VersionInfo.ProductVersion ## Create Text File with Autodesk DWG TrueView 2021 File Detection Method $FilePath = "C:\Windows\Temp\Autodesk_DWG_TrueView_2021_Detection_Method.txt" New-Item -Path "$FilePath" -Force Set-Content -Path "$FilePath" -Value "If([String](Get-Item -Path `"`$Env:ProgramFiles\$DWGTrueViewPath`" -ErrorAction SilentlyContinue).VersionInfo.ProductVersion -ge `"$ProductVersion`"){" Add-Content -Path "$FilePath" -Value "Write-Host `"Installed`"" Add-Content -Path "$FilePath" -Value "Exit 0" Add-Content -Path "$FilePath" -Value "}" Add-Content -Path "$FilePath" -Value "else {" Add-Content -Path "$FilePath" -Value "Exit 1" Add-Content -Path "$FilePath" -Value "}" Invoke-Item $FilePath
- Click Run Script (F5)
- A text file will open with the Autodesk DWG TrueView 2021 Detection Method script required to detect the current version of Autodesk DWG TrueView 2021 that is installed on the device you are running the script from.
Example:
If([String](Get-Item -Path "$Env:ProgramFiles\Autodesk\DWG TrueView 2021 - English\dwgviewr.exe" -ErrorAction SilentlyContinue).VersionInfo.ProductVersion -ge "R24.0.172.0.0"){ Write-Host "Installed" Exit 0 } else { Exit 1 }
- Copy the Autodesk DWG TrueView 2021 Detection Method script content into the Custom Detection Rules (Script)
- Microsoft Endpoint Manager Configuration Manager (MEMCM / SCCM)
- Microsoft Intune
Autodesk DWG TrueView 2021 (Registry Detection Method)
- Install the version of Autodesk DWG TrueView 2021 you want to deploy on a test box or VM
- Check out the following posts for further details
- Open Windows PowerShell ISE by Right-Clicking on Windows PowerShell ISE and selecting Run as Administrator
- Copy the following code into the Windows PowerShell ISE
## Check for Autodesk DWG TrueView 2021 (Registry Detection Method) $DWGTrueView = Get-ChildItem -Path "HKLM:\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall" | Get-ItemProperty | Where-Object {$_.DisplayName -match 'Autodesk DWG TrueView 2021' } | Select-Object -Property DisplayName, DisplayVersion, PSChildName $DWGTrueView.DisplayVersion $DWGTrueView.PSChildName ## Create Text File with Autodesk DWG TrueView 2021 Registry Detection Method $FilePath = "C:\Windows\Temp\Autodesk_DWG_TrueView_2021_Detection_Method.txt" New-Item -Path "$FilePath" -Force Set-Content -Path "$FilePath" -Value "If([Version](Get-ItemPropertyValue -Path 'HKLM:\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall\$($DWGTrueView.PSChildName)' -Name DisplayVersion -ea SilentlyContinue) -ge '$($DWGTrueView.DisplayVersion)') {" Add-Content -Path "$FilePath" -Value "Write-Host `"Installed`"" Add-Content -Path "$FilePath" -Value "Exit 0" Add-Content -Path "$FilePath" -Value "}" Add-Content -Path "$FilePath" -Value "else {" Add-Content -Path "$FilePath" -Value "Exit 1" Add-Content -Path "$FilePath" -Value "}" Invoke-Item $FilePath
- Click Run Script (F5)
- A text file will open with the Autodesk DWG TrueView 2021 Detection Method script required to detect the current version of Autodesk DWG TrueView 2021 that is installed on the device you are running the script from.
Example:
If([Version](Get-ItemPropertyValue -Path 'HKLM:\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall\DWG TrueView 2021 - English' -Name DisplayVersion -ea SilentlyContinue) -ge '24.0.172.0') { Write-Host "Installed" Exit 0 } else { Exit 1 }
- Copy the Autodesk DWG TrueView 2021 Detection Method script content into the Custom Detection Rules (Script)
- Microsoft Endpoint Manager Configuration Manager (MEMCM / SCCM)
- Microsoft Intune
Always make sure to test everything in a development environment prior to implementing anything into production. The information in this article is provided “As Is” without warranty of any kind.